![](https://reachora-public-videos.imgix.net/v/24/7/c/27b4d2-cb2d-4acf-914e-4a929088a0db/thumbnails/image_1.jpg)
![](https://reachora-public-videos.imgix.net/v/19/3/a/99b10e-8772-4e7e-82c2-da15262cf543/thumbnails/image_4.jpg)
![](https://reachora-public-videos.imgix.net/v/24/6/8/6442a6-a8a7-40e1-b7c9-b7636b6dc10e/thumbnails/image_1.jpg)
![](https://reachora-public-videos.imgix.net/v/69/7/4/6e5a5f-cfea-4108-a7cf-36110e2b61e5/thumbnails/image_1.jpg)
![](https://reachora-public-thumbnails.imgix.net/uploaded/production/7e1656ac-e6b6-456c-b35c-779ae59ccc71.jpg)
![](https://reachora-public-videos.imgix.net/v/15/3/8/56b7cd-4cec-4fa3-bcaf-de8f9d141976/thumbnails/image_48.jpg)
State of the art Renal Artery Denervation treatment using Medtronic Spyral Catheter
Use of Medtronic Simplicity Spyral multi-electrode Catheter to perform percutaneous renal artery nerve denervation.
Overview
Dr Davies and Dr Sen perform a live case demonstration from the...
Use of Medtronic Simplicity Spyral multi-electrode Catheter to perform percutaneous renal artery nerve denervation.
Overview
Dr Davies and Dr Sen perform a live case demonstration from the Hammersmith Hospital London. Using the Medtronic Symplicity Spyral Multi-Electrode catheter system, they perform renal artery denervation in a patient with sympathetic overacitivation. They demonstrate how to perform a safe and effective renal deneravation procedure using the latest branch and trunk denervation procedure.
Learning Objectives
The Symplicity Spyral catheter has 4 gold electrodes which allow simultaneous delivery of radio frequency energy at a depth of 2-6mm. The automated algorithms in the generator box continually monitior temperature and impendence at each electrode to allow simultaneous radio frequency ablation at 4 sites.
- Learn how to perform renal denervation using the Symplicity Spyral catheter
- Best guide cathether and best guide wire to use
- Review approach for safely performing branch denervation
- Understand catheter design and how to deploy safely
- Experience multi-electrode generator, and its application for safe and effective denervation.
Target Audience
- Interventionalists with an interest in renal denervation
- Hypertension specialists
- General practitioners with interest in hypertension management
Featuring
- Dr Justin Davies, Consultant Cardiologist, Hammersmith Hospital, Imperial College Healthcare NHS Trust
- Dr Sayan Sen, Consultant Cardiologist, Hammersmith Hospital, Imperial College Healthcare NHS Trust
Disclosures
Dr Justin Davies is a consultant for Medtronic.
Simple Education, is a leading provider of coronary physiology and intracoronary imaging courses to aid treatment of complex coronary artery disease.